<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>http://wiki.scalelogicinc.com/index.php?action=history&amp;feed=atom&amp;title=UPS_status</id>
	<title>UPS status - Revision history</title>
	<link rel="self" type="application/atom+xml" href="http://wiki.scalelogicinc.com/index.php?action=history&amp;feed=atom&amp;title=UPS_status"/>
	<link rel="alternate" type="text/html" href="http://wiki.scalelogicinc.com/nx/index.php?title=UPS_status&amp;action=history"/>
	<updated>2026-05-05T04:27:19Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.44.5</generator>
	<entry>
		<id>http://wiki.scalelogicinc.com/nx/index.php?title=UPS_status&amp;diff=1189&amp;oldid=prev</id>
		<title>Ma-W: 1 revision</title>
		<link rel="alternate" type="text/html" href="http://wiki.scalelogicinc.com/nx/index.php?title=UPS_status&amp;diff=1189&amp;oldid=prev"/>
		<updated>2019-03-25T15:21:07Z</updated>

		<summary type="html">&lt;p&gt;1 revision&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;1&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;1&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 15:21, 25 March 2019&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-notice&quot; lang=&quot;en&quot;&gt;&lt;div class=&quot;mw-diff-empty&quot;&gt;(No difference)&lt;/div&gt;
&lt;/td&gt;&lt;/tr&gt;&lt;/table&gt;</summary>
		<author><name>Ma-W</name></author>
	</entry>
	<entry>
		<id>http://wiki.scalelogicinc.com/nx/index.php?title=UPS_status&amp;diff=1188&amp;oldid=prev</id>
		<title>Ma-W at 11:44, 15 March 2019</title>
		<link rel="alternate" type="text/html" href="http://wiki.scalelogicinc.com/nx/index.php?title=UPS_status&amp;diff=1188&amp;oldid=prev"/>
		<updated>2019-03-15T11:44:15Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;Displays current status of Uninterruptible Power Supply unit and battery.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Possible status symbols&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
{| style=&amp;quot;width: 500px&amp;quot; class=&amp;quot;cke_show_border&amp;quot; cellspacing=&amp;quot;1&amp;quot; cellpadding=&amp;quot;1&amp;quot; border=&amp;quot;0&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
| style=&amp;quot;text-align: center&amp;quot; | &amp;#039;&amp;#039;&amp;#039;OL&amp;#039;&amp;#039;&amp;#039;&amp;lt;br/&amp;gt;&lt;br /&gt;
| On line (no power failure)&amp;lt;br/&amp;gt;&lt;br /&gt;
|-&lt;br /&gt;
| style=&amp;quot;text-align: center&amp;quot; | &amp;#039;&amp;#039;&amp;#039;OB&amp;#039;&amp;#039;&amp;#039;&amp;lt;br/&amp;gt;&lt;br /&gt;
| On battery&amp;lt;br/&amp;gt;&lt;br /&gt;
|-&lt;br /&gt;
| style=&amp;quot;text-align: center&amp;quot; | &amp;#039;&amp;#039;&amp;#039;LB&amp;#039;&amp;#039;&amp;#039;&amp;lt;br/&amp;gt;&lt;br /&gt;
| Low battery&amp;lt;br/&amp;gt;&lt;br /&gt;
|-&lt;br /&gt;
| style=&amp;quot;text-align: center&amp;quot; | &amp;#039;&amp;#039;&amp;#039;SB&amp;#039;&amp;#039;&amp;#039;&amp;lt;br/&amp;gt;&lt;br /&gt;
| Shutdown load&amp;lt;br/&amp;gt;&lt;br /&gt;
|-&lt;br /&gt;
| style=&amp;quot;text-align: center&amp;quot; | &amp;#039;&amp;#039;&amp;#039;CP&amp;#039;&amp;#039;&amp;#039;&amp;lt;br/&amp;gt;&lt;br /&gt;
| Cable power&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;#039;&amp;#039;&amp;#039;Configuration&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
Connection to UPS can be configured in Console by pressing CTRL+ALT+W and choosing option 4. UPS Configuration. Enter settings according to your hardware specification:&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Select the UPS vendor for your UPS device. Vendors &amp;#039;&amp;#039;&amp;#039;APC&amp;#039;&amp;#039;&amp;#039; and &amp;#039;&amp;#039;&amp;#039;MGE&amp;#039;&amp;#039;&amp;#039; are available.&lt;br /&gt;
&lt;br /&gt;
;&amp;lt;br/&amp;gt;&lt;br /&gt;
;&amp;#039;&amp;#039;&amp;#039;UPS mode&amp;#039;&amp;#039;&amp;#039;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
:;Single&amp;lt;br/&amp;gt;&lt;br /&gt;
::This option determines that the server is the only system attached to this UPS and that there is no action necessary to do a remote shutdown for other systems in the network.&lt;br /&gt;
:;Server&amp;lt;br/&amp;gt;&lt;br /&gt;
::This option determines that the server is connected to the UPS and sends a signal through the network to shut down other systems in the network.&lt;br /&gt;
:;Client&amp;lt;br/&amp;gt;&lt;br /&gt;
::This option determines that the server reacts to a power down-signal from the UPS server.&lt;br /&gt;
&lt;br /&gt;
:When using an &amp;#039;&amp;#039;&amp;#039;APC&amp;#039;&amp;#039;&amp;#039;-originated device with the &amp;#039;&amp;#039;&amp;#039;Server UPS&amp;#039;&amp;#039;&amp;#039; mode server net port is fixed and set to 3551.&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
:When using an &amp;#039;&amp;#039;&amp;#039;APC&amp;#039;&amp;#039;&amp;#039;-originated device with the &amp;#039;&amp;#039;&amp;#039;Client UPS&amp;#039;&amp;#039;&amp;#039; mode enabled the following fields are available:&lt;br /&gt;
&lt;br /&gt;
::;Server Net port&amp;lt;br/&amp;gt;&lt;br /&gt;
:::TCP port on which the&amp;amp;nbsp; UPS client is connecting to the UPS server.&amp;lt;br/&amp;gt;&lt;br /&gt;
::;Server IP&amp;lt;br/&amp;gt;&lt;br /&gt;
:::IP address of the master APC UPS.&lt;br /&gt;
&lt;br /&gt;
:When using an &amp;#039;&amp;#039;&amp;#039;MGE&amp;#039;&amp;#039;&amp;#039;-originated device with the &amp;#039;&amp;#039;&amp;#039;Master UPS&amp;#039;&amp;#039;&amp;#039; mode enabled the following fields are available:&lt;br /&gt;
&lt;br /&gt;
::;User name&lt;br /&gt;
:::User name allowed to connect from the slave UPS.&lt;br /&gt;
::;Password&lt;br /&gt;
:::Password for the user name above.&amp;lt;br/&amp;gt;&lt;br /&gt;
::;Slave IP&lt;br /&gt;
:::IP address of the slave MGE UPS. It is possible to specify multiple addresses separated by semicolon.&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
:When using an &amp;#039;&amp;#039;&amp;#039;MGE&amp;#039;&amp;#039;&amp;#039;-originated device with the &amp;#039;&amp;#039;&amp;#039;Slave UPS&amp;#039;&amp;#039;&amp;#039; mode the following fields are available:&lt;br /&gt;
&lt;br /&gt;
::;User name&lt;br /&gt;
:::User name which will connect to the master UPS. It needs to be the same as the one on the master UPS.&lt;br /&gt;
::;Password&lt;br /&gt;
:::Password for the user name above.&lt;br /&gt;
::;Master IP&lt;br /&gt;
:::IP address of the master MGE UPS.&lt;br /&gt;
&lt;br /&gt;
;&amp;#039;&amp;#039;&amp;#039;UPS model&amp;#039;&amp;#039;&amp;#039;&amp;lt;br/&amp;gt;&lt;br /&gt;
:The model of your UPS device.&lt;br /&gt;
;&amp;#039;&amp;#039;&amp;#039;Port&amp;#039;&amp;#039;&amp;#039;&amp;lt;br/&amp;gt;&lt;br /&gt;
:Port to which the UPS is connected.&amp;lt;br/&amp;gt;&lt;br /&gt;
;&amp;#039;&amp;#039;&amp;#039;Cable type&amp;#039;&amp;#039;&amp;#039;&amp;lt;br/&amp;gt;&lt;br /&gt;
:Cable type for your APC UPS.&lt;br /&gt;
;&amp;#039;&amp;#039;&amp;#039;Timeout&amp;#039;&amp;#039;&amp;#039;&amp;lt;br/&amp;gt;&lt;br /&gt;
:The timeout defines the time between a power failure and the moment the system shuts down.&amp;lt;br/&amp;gt;&lt;br /&gt;
;&amp;#039;&amp;#039;&amp;#039;Timeout - Battery Limit&amp;#039;&amp;#039;&amp;#039;&amp;lt;br/&amp;gt;&lt;br /&gt;
:This option enables you to sustain the system as long as the battery holds (the system will shut down when the battery charge drops to 5% or when there are 3 minutes left to total battery discharge).&amp;lt;br/&amp;gt;&lt;br /&gt;
:&amp;lt;br/&amp;gt;&lt;br /&gt;
:&amp;#039;&amp;#039;&amp;#039;APC&amp;#039;&amp;#039;&amp;#039; - This option works for all Smart UPS models and dumb UPSes with cables that support low battery detection (only testing can determine this point).&amp;lt;br/&amp;gt;&lt;br /&gt;
:&amp;lt;br/&amp;gt;&lt;br /&gt;
;&amp;#039;&amp;#039;&amp;#039;Turn off UPS after system shutdown&amp;#039;&amp;#039;&amp;#039;&amp;lt;br/&amp;gt;&lt;br /&gt;
:This will turn off the UPS device after the time period set in the &amp;#039;&amp;#039;&amp;#039;Shutdown grace delay (SLEEP)&amp;#039;&amp;#039;&amp;#039; parameter in the UPS EEPROM expires.&lt;br /&gt;
&amp;lt;div class=&amp;quot;noteheader&amp;quot;&amp;gt;Note&amp;lt;/div&amp;gt;&amp;lt;div class=&amp;quot;note&amp;quot;&amp;gt;When using slave and master UPS modes, all UPS devices need to come from the same vendor.&amp;lt;br/&amp;gt;&amp;lt;/div&amp;gt;&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;#039;&amp;#039;&amp;#039;SNMP UPS&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
To communicate with UPS via SNMP choose MGE as UPS vendor and following settings:&lt;br /&gt;
&lt;br /&gt;
[[File:Snmp ups.jpg|none|SNMP]]&lt;br /&gt;
&lt;br /&gt;
:&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[Category:Help topics]]&lt;/div&gt;</summary>